Commands and functions > Viewport > New viewport
  
New viewport
Ribbon:
Tab ATHENA > Group Drawing aids > New viewport
Menu:
ATHENA > Viewport > New viewport
Toolbar:
ATH Viewport > New viewport
Command input:
ath_mf_vp_neu
You create a new viewport with scale using this command. The scale is set in the viewport using the zoom factor. For each new viewport ATHENA creates a dedicated dimension layer dependent on the scale.
When you execute the command, the Dialog box Viewport with scale is started.
Dialog box Viewport with scale
db_ath_mf_vp_neu
Layout
Defines the layout in which the viewport is to be produced.
Scale
Specifies the scale of the viewport. In the input field Factor you can define a new scale factor. Here, the scales from the AutoCAD list of scales are made available. You will find further information on this subject in the AutoCAD documentation.
When you close the dialog box with OK, the following input request appears:
Input request 
Specify first point of window or [?]:
Use the mouse or enter coordinates to specify the first corner point of the viewport.
With the option ? you call the help.
Specify second point of viewport or [?]:
Use the mouse or enter coordinates to specify the second corner point of the viewport diagonally opposite.
Specify center point for viewport or [?]:
Determine the center point of the viewport. For this, first zooming to the drawing limits occurs in the viewport. Once you have specified the center point, the defined scale is set.